{"id":1376,"date":"2016-10-12T13:40:48","date_gmt":"2016-10-12T11:40:48","guid":{"rendered":"http:\/\/www.rolig.dk\/?p=1376"},"modified":"2016-10-12T13:40:48","modified_gmt":"2016-10-12T11:40:48","slug":"update-dell-bios-during-osd","status":"publish","type":"post","link":"https:\/\/rolig.dk\/?p=1376","title":{"rendered":"Update Dell bios during OSD"},"content":{"rendered":"<p>&nbsp;<\/p>\n<p>In this post I will show you how to update the bios on a Dell during OSD. I have created the following folder structure for the Dell bios updates: <br \/>SCCM_SHARE\/Dell Bios Update\/MODEL\/BIOS_FILE<br \/><a href=\"https:\/\/rolig.dk\/wp-content\/uploads\/2016\/10\/image-2.png\"><img loading=\"lazy\" decoding=\"async\" title=\"image\" style=\"border-left-width: 0px; border-right-width: 0px; background-image: none; border-bottom-width: 0px; padding-top: 0px; padding-left: 0px; display: inline; padding-right: 0px; border-top-width: 0px\" border=\"0\" alt=\"image\" src=\"https:\/\/rolig.dk\/wp-content\/uploads\/2016\/10\/image_thumb-2.png\" width=\"527\" height=\"154\"><\/a><\/p>\n<p>1. Download the bios you want to deploy from Dell support site. In this example the file is called \u201cO7010A23.exe\u201d<\/p>\n<p>2. Create a SCCM package with the bios file that you downloaded in step 1.<\/p>\n<p>3. Create a new group in your task sequence and call it \u201cBios Tasks Windows 10\u201d. I create the group because I want only this step to run it is Windows that I deploy. I control that with a SCCM variable.<\/p>\n<p>4. Create a new group under \u201cBios Tasks Windows 10\u201d and call it \u201cDell\u201d with the following condition (SELECT * FROM Win32_ComputerSystem WHERE Manufacturer LIKE &#8220;%Dell%&#8221;)<br \/><a href=\"https:\/\/rolig.dk\/wp-content\/uploads\/2016\/10\/image.png\"><img loading=\"lazy\" decoding=\"async\" title=\"image\" style=\"border-left-width: 0px; border-right-width: 0px; background-image: none; border-bottom-width: 0px; padding-top: 0px; padding-left: 0px; display: inline; padding-right: 0px; border-top-width: 0px\" border=\"0\" alt=\"image\" src=\"https:\/\/rolig.dk\/wp-content\/uploads\/2016\/10\/image_thumb.png\" width=\"510\" height=\"209\"><\/a><\/p>\n<p>5. Create a new group under \u201cDell\u201d and call it \u201cOptiPlex 7010\u201d, or the model you want to update, with the following condition (SELECT * FROM Win32_ComputerSystem WHERE Manufacturer LIKE &#8220;%OptiPlex 7010%&#8221;)<br \/><a href=\"https:\/\/rolig.dk\/wp-content\/uploads\/2016\/10\/image-1.png\"><img loading=\"lazy\" decoding=\"async\" title=\"image\" style=\"border-left-width: 0px; border-right-width: 0px; background-image: none; border-bottom-width: 0px; padding-top: 0px; padding-left: 0px; display: inline; padding-right: 0px; border-top-width: 0px\" border=\"0\" alt=\"image\" src=\"https:\/\/rolig.dk\/wp-content\/uploads\/2016\/10\/image_thumb-1.png\" width=\"514\" height=\"206\"><\/a><\/p>\n<p>6. Add a Run Command Line step and call it \u201cBios Update A23 for Dell Optiplex 7010\u201d with the following settings <\/p>\n<p>a. Command Line: 7010-A23\/O7010A23.exe \/s \/f \/r \/p=&#8221;PASSWORD&#8221; \/l=&#8221;C:\\Temp\\DellBiosUpdateA23.txt&#8221;<\/p>\n<p>b. Package = The SCCM package you created in step 2.<\/p>\n<p><a href=\"https:\/\/rolig.dk\/wp-content\/uploads\/2016\/10\/image-3.png\"><img loading=\"lazy\" decoding=\"async\" title=\"image\" style=\"border-left-width: 0px; border-right-width: 0px; background-image: none; border-bottom-width: 0px; padding-top: 0px; padding-left: 0px; display: inline; padding-right: 0px; border-top-width: 0px\" border=\"0\" alt=\"image\" src=\"https:\/\/rolig.dk\/wp-content\/uploads\/2016\/10\/image_thumb-3.png\" width=\"519\" height=\"500\"><\/a><\/p>\n<p>c. Add a condition for each older bios version. This will run the step is the bios version is one of them in the list. (Select * From Win32_BIOS WHERE SMBIOSBIOSVersion LIKE &#8220;%A01%&#8221;)<br \/><a href=\"https:\/\/rolig.dk\/wp-content\/uploads\/2016\/10\/image-4.png\"><img loading=\"lazy\" decoding=\"async\" title=\"image\" style=\"border-left-width: 0px; border-right-width: 0px; background-image: none; border-bottom-width: 0px; padding-top: 0px; padding-left: 0px; display: inline; padding-right: 0px; border-top-width: 0px\" border=\"0\" alt=\"image\" src=\"https:\/\/rolig.dk\/wp-content\/uploads\/2016\/10\/image_thumb-4.png\" width=\"521\" height=\"491\"><\/a><\/p>\n<p>The step look like this in the task sequence:<\/p>\n<p><a href=\"https:\/\/rolig.dk\/wp-content\/uploads\/2016\/10\/image-27.png\"><img loading=\"lazy\" decoding=\"async\" title=\"image\" style=\"border-top: 0px; border-right: 0px; background-image: none; border-bottom: 0px; padding-top: 0px; padding-left: 0px; border-left: 0px; display: inline; padding-right: 0px\" border=\"0\" alt=\"image\" src=\"https:\/\/rolig.dk\/wp-content\/uploads\/2016\/10\/image_thumb-27.png\" width=\"524\" height=\"114\"><\/a><\/p>\n<p>That\u2019s it.<\/p>\n<a class=\"synved-social-button synved-social-button-share synved-social-size-48 synved-social-resolution-single synved-social-provider-twitter nolightbox\" data-provider=\"twitter\" target=\"_blank\" rel=\"nofollow\" title=\"Share on Twitter\" href=\"https:\/\/twitter.com\/intent\/tweet?url=https%3A%2F%2Frolig.dk%2Findex.php%3Frest_route%3D%252Fwp%252Fv2%252Fposts%252F1376&amp;text=Hey%20check%20this%20out\" style=\"font-size: 0px;width:48px;height:48px;margin:0;margin-bottom:5px;margin-right:5px\"><img loading=\"lazy\" decoding=\"async\" alt=\"twitter\" title=\"Share on Twitter\" class=\"synved-share-image synved-social-image synved-social-image-share\" width=\"48\" height=\"48\" style=\"display: inline;width:48px;height:48px;margin: 0;padding: 0;border: none;box-shadow: none\" src=\"https:\/\/rolig.dk\/wp-content\/plugins\/social-media-feather\/synved-social\/addons\/extra-icons\/image\/social\/circle\/96x96\/twitter.png\" \/><\/a><a class=\"synved-social-button synved-social-button-share synved-social-size-48 synved-social-resolution-single synved-social-provider-linkedin nolightbox\" data-provider=\"linkedin\" target=\"_blank\" rel=\"nofollow\" title=\"Share on Linkedin\" href=\"https:\/\/www.linkedin.com\/shareArticle?mini=true&amp;url=https%3A%2F%2Frolig.dk%2Findex.php%3Frest_route%3D%252Fwp%252Fv2%252Fposts%252F1376&amp;title=Update%20Dell%20bios%20during%20OSD\" style=\"font-size: 0px;width:48px;height:48px;margin:0;margin-bottom:5px\"><img loading=\"lazy\" decoding=\"async\" alt=\"linkedin\" title=\"Share on Linkedin\" class=\"synved-share-image synved-social-image synved-social-image-share\" width=\"48\" height=\"48\" style=\"display: inline;width:48px;height:48px;margin: 0;padding: 0;border: none;box-shadow: none\" src=\"https:\/\/rolig.dk\/wp-content\/plugins\/social-media-feather\/synved-social\/addons\/extra-icons\/image\/social\/circle\/96x96\/linkedin.png\" \/><\/a>","protected":false},"excerpt":{"rendered":"<p>&nbsp; In this post I will show you how to update the bios on a Dell during OSD. I have created the following folder structure for the Dell bios updates: SCCM_SHARE\/Dell Bios Update\/MODEL\/BIOS_FILE 1. Download the bios you want to deploy from Dell support site. In this example the file is called \u201cO7010A23.exe\u201d 2. Create [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_feature_clip_id":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_post_was_ever_published":false},"categories":[4],"tags":[35],"class_list":["post-1376","post","type-post","status-publish","format-standard","hentry","category-sccm","tag-sccmdellbios"],"jetpack_featured_media_url":"","jetpack_sharing_enabled":true,"_links":{"self":[{"href":"https:\/\/rolig.dk\/index.php?rest_route=\/wp\/v2\/posts\/1376","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/rolig.dk\/index.php?rest_route=\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/rolig.dk\/index.php?rest_route=\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/rolig.dk\/index.php?rest_route=\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/rolig.dk\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=1376"}],"version-history":[{"count":0,"href":"https:\/\/rolig.dk\/index.php?rest_route=\/wp\/v2\/posts\/1376\/revisions"}],"wp:attachment":[{"href":"https:\/\/rolig.dk\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=1376"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/rolig.dk\/index.php?rest_route=%2Fwp%2Fv2%2Fcategories&post=1376"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/rolig.dk\/index.php?rest_route=%2Fwp%2Fv2%2Ftags&post=1376"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}